Step 1: Technician Intake Enter equipment & service log Annualized rate calculates live Step 2: Statutory Deliverable Review Official EPA 608 Dossier
STEP 1 · INTAKE CONTROLS Enter equipment specs & service log below
01

Job & Technician Identification

Identify the service call, dispatch ticket, and EPA-certified technician.

02

Equipment & Statutory Category (40 CFR § 82.157)

Select appliance classification to enforce EPA statutory leak rate thresholds.

03

Refrigerant Mass Balance & EPA Leak Calculation

Precision decimal entries with fast tactile macro steppers (-1, -5, +1, +5, +25 lbs).

Statutory Compliance Citation: 40 CFR § 82.157 Annualized Leak Rate (%) = (Pounds Added ÷ Full Charge) × (365 ÷ Days Since Last Addition) × 100%
lbs
lbs
lbs
days
Default 365 for first service or annual inspection
Real-Time Reactive Net Balance Initial Charge + Added - Recovered = Net Balance
Initial Charge 0.0 lbs
+
Added 0.0 lbs
-
Recovered 0.0 lbs
=
Net System Balance 0.0 lbs
Statutory Leak Evaluation (40 CFR § 82.157)
0.0% Annualized Leak Rate EPA Threshold: Exempt (<50 lbs)
STATUTORY EXEMPT (<50 LBS)

EPA Category: Comfort / Small Appliance (<50 lbs) - Section 608 Venting Prohibition Applies; Statutory Leak Rate Thresholds Exempt

04

Technician Observations & Service Notes

Document leak check method, readings, components serviced, and customer observations.

05

EPA Compliance & Completion Checklist

Mandatory Section 608 procedural verifications before filing.

STEP 2 · STATUTORY DELIVERABLE Official 40 CFR § 82.157 Service Dossier & Certificate
EPA 608

HVAC FIELD SERVICE & COMPLIANCE LEDGER

Official Refrigerant Environmental Protection Agency Record

Certificate #: EPA-608-2026-8492
Work Order: WO-2026-8492
Generated: Sep 9, 2026 • 14:00 UTC

EPA Section 608 Refrigerant Compliance & Leak Rate Certificate

Statutory Documentation of Refrigerant Mass Balance & Annualized Leak Determination under 40 CFR § 82.157

STATUTORY EXEMPT (<50 LBS)

EPA Category: Comfort / Small Appliance (<50 lbs): Section 608 Venting Prohibition Applies; Statutory Leak Rate Thresholds Exempt

Facility & Service Details

Equipment & Regulatory Profile

Refrigerant Mass Balance & Statutory Calculation

Refrigerant Type Full System Charge Added Today Recovered Today Net Balance Days Since Added Calculated Leak Rate EPA Statutory Limit Compliance Status
R-410A 8.5 lbs 0.5 lbs 0.0 lbs 9.0 lbs 365 days 5.9% Exempt (<50 lbs) EXEMPT

Technician Narrative & Diagnostic Observations

CERTIFIED TECHNICIAN ATTESTATION

Touch signature on glass

Sarah Jenkins

EPA Universal Card #: 608-UNIV-884210

Date: September 7, 2026

FACILITY OWNER / MANAGER ACKNOWLEDGMENT

Touch signature on glass

Facility Owner / Designated Representative

Authorized Client Signatory

Date: September 7, 2026